IRC R1003 & NFPA 211 Chimney Flue Block Takeoff

Cinder Block Chimney Calculator

Estimate 16×16 and 16×20 cinder block chimney flue units, 2-ft clay flue liners, 50-lb refractory mortar pails, 80-lb Type S masonry mortar bags, and 4-inch cast concrete crown bags.

Direct Answer: A 24-ft chimney using 16×16 cinder block flue units requires 38 chimney blocks (with 5% waste), 12 two-foot clay flue liners, 3 pails of refractory mortar, 2 Type S mortar bags, and 2 concrete bags (0.78 cu ft) for a 4-inch crown.
Vertical Coursing1.5 / ft8" nominal block height
Clay Flue Liners24" (2 ft)0.5 liner sections / ft
Dual MortarsC199 + Type SRefractory inner · Type S outer
Concrete Crown4" + 2" DripOverhangs all 4 faces

Advertisement

Live Takeoff (24 ft · 16"×16" (8"×8" Flue))
38Flue Blocks· 12 liners · 3 refractory pails
Details

Vertical height above footing or firebox smoke chamber (4–60 ft)

Standard 8" nominal height (1.5 courses per vertical ft)

Planning example per chimney block

Planning example per 24" clay flue liner

NFPA 211 & IRC R1003 Chimney Clearance & Code Reminder:

A 24-ft chimney stack needs 36 net 8" courses with staggered clay liner joints offset from outer block courses. Maintain the code-required air space between clay liners and masonry walls, use non-combustible refractory mortar inside flue joints, and confirm footing size, seismic straps, and 3-2-10 roof height clearance under NFPA 211 / local IRC R1003 with a licensed chimney or structural professional.

Selected Assembly Basis (16"×16" (8"×8" Flue)):

Pairs with 8"×8" nominal clay flue liner and a 4"-thick cast concrete chimney crown (20" × 20" (with 2" drip overhang)) extending 2" past all four faces with a perimeter drip kerf and compressible bond-break joint around the top liner.

Chimney Material Takeoff

Stack Units (24 ft · 5% Block Waste)

38

Chimney Blocks

36 net courses (1.5/ft)

12

2-ft Clay Liners

24" sections (0.5/ft)

Refractory Pails

3 × 50 lb

~1 pail / 4 liner joints

Type S Mortar

2 × 80 lb

~1 bag / 22 outer blocks

4" Cast Concrete Crown2 × 80-lb bags
Net Crown Volume0.78 cu ft20" × 20" (with 2" drip overhang)
Illustrative Block & Liner BudgetPlanning Example
Chimney Blocks$247.0038 × $6.50
Clay Flue Liners$264.0012 × $22.00

Illustrative subtotal: $511.00 (blocks + liners only; excludes mortar, concrete cap, flashing, rebar, footing, and labor).

CMU estimates use nominal face dimensions and illustrative mortar yields (30 standard 8-inch units per 80-lb premix bag before waste; thickness adjustments apply). Confirm product yields, unit core volumes, supplier pack sizes and local prices before ordering. Reinforcement quantities are material allowances; laps, hooks, embedment and engineered design are excluded.

Advertisement

Worked 24-ft Cinder Block Chimney Takeoff (16×16 Flue Block)

Every standard hollow cinder block chimney unit is molded to an 8-inch nominal height (7-5/8" actual height plus a 3/8" mortar bed joint), meaning three courses rise exactly 24 inches—or 1.5 blocks per vertical foot. Standard ASTM C315 rectangular clay flue liners come in 24-inch (2-ft) sections, matching every three outer block courses while letting masons stagger horizontal liner joints away from outer block bed joints.

Worked Example: 24-ft Two-Story Home Chimney (16"×16" Block, 5% Waste)

1. Chimney Flue Blocks = ceil(24 ft × 1.5 blocks/ft × 1.05) = ceil(37.8) = 38 flue blocks (36 net courses + 5% waste)

2. 2-ft Clay Flue Liners = ceil(24 ft ÷ 2 ft/section) = 12 × 24" clay liner sections (8"×8" nominal flue)

3. Refractory Mortar (ASTM C199) = ceil(12 liners ÷ 4) = 3 × 50-lb refractory mortar pails

4. Type S Masonry Mortar (ASTM C270) = ceil(38 blocks ÷ 22) = 2 × 80-lb Type S mortar bags

5. 4" Cast Concrete Crown (2" overhang = 20"×20" cap − 8"×8" flue) = ((400 − 64) × 4) ÷ 1,728 = 0.78 cu ft → ceil(0.78 ÷ 0.60) = 2 × 80-lb concrete premix bags

Notice that unit prices, mortar yields, and pallet packaging vary by regional block manufacturer and joint thickness. Treat all dollar subtotals in the calculator as illustrative planning examples and confirm local yard stock before ordering.

Table 1: 16×16 vs 16×20 Chimney Block & Clay Flue Liner Chart

The matrix below compares the two standard single-flue cinder block chimney formats—showing compatible ASTM C315 clay flue liners, 4-inch crown concrete volume, and stack takeoffs (with 5% block waste) from 12 ft to 32 ft.

Block FormatActual Outer SizeMatching Clay Liner4" Crown (2" Overhang)12-ft Stack20-ft Stack24-ft Stack32-ft Stack
16" × 16" Square Chimney Block15-5/8" × 15-5/8" × 7-5/8"8" × 8" Nominal (7-1/4" OD)20" × 20" (0.78 cu ft / 2 bags)19 blocks · 6 liners32 blocks · 10 liners38 blocks · 12 liners51 blocks · 16 liners
16" × 20" Rectangular Chimney Block15-5/8" × 19-5/8" × 7-5/8"8" × 12" or 13" × 13" Nominal20" × 24" (0.89 cu ft / 2 bags)19 blocks · 6 liners32 blocks · 10 liners38 blocks · 12 liners51 blocks · 16 liners

Table 2: Refractory vs Type S Mortar & Concrete Crown Spec

A durable masonry chimney relies on three distinct cementitious materials—each matched to its thermal and weather exposure zone. Never substitute exterior Type S mortar inside clay flue liner joints, and never use standard thin mortar wash as a substitute for a reinforced 4-inch overhanging concrete crown.

MaterialApplicable StandardChimney ZoneIllustrative Yield BasisField Installation Note
Refractory Mortar (50-lb Pails)ASTM C199 (Medium/High Duty)Clay flue liner tongue-and-groove / butt joints~1 pail per 4 two-foot clay liner sectionsNon-water-soluble; wipe interior joints smooth flush with liner bore.
Type S Masonry Mortar (80-lb Bags)ASTM C270 Type S (1,800 psi)Outer cinder block chimney bed & head joints~1 bag per 22 chimney flue blocksProvides high lateral bond strength for exterior wind & freeze-thaw exposure.
Cast Concrete Chimney Crown (80-lb Bags)ASTM C387 (≥3,500–4,000 psi mix)4"-thick top cap with 2" drip overhang all sides0.60 cu ft yield per 80-lb bag (rounded up)Isolate clay flue liner from concrete with 1/4"–1/2" expansion wrap & drip kerf.

IRC R1003 & NFPA 211 Chimney Clearances, Reinforcement & Crown Details

Material counts are only one piece of safe chimney construction. Masonry chimneys carry concentrated vertical dead loads onto frost-protected concrete footings and experience intense internal thermal gradients. Before starting any chimney stack, review these code-referenced checkpoints under IRC R1003 and NFPA 211 with your local building inspector and a licensed chimney or structural professional:

Air Space & Combustible Framing Clearances

Maintain the required air space between the exterior of clay flue liners and the interior face of cinder block chimney walls—never pack the annular cavity solid with wet mortar. In addition, IRC R1003.18 generally requires a 2-inch clearance to combustible wood framing for interior chimneys (1 inch for exterior chimneys), sealed with non-combustible fireblocking at each floor and ceiling penetration.

Footings, Vertical Rebar & 3-2-10 Termination

Support the stack on a reinforced concrete footing at least 12 inches thick projecting 6 inches beyond the chimney base on all sides below frost depth (IRC R1003.2), verify vertical reinforcing steel and seismic anchorage straps where locally mandated, and terminate the flue at least 3 ft above the roof penetration and 2 ft higher than any structure within 10 ft.

Crown Bond-Break Joint & Drip Kerf Protection

When pouring the 4-inch concrete chimney crown, wrap the top protruding clay flue tile with a 1/4-inch to 1/2-inch foam or ceramic-fiber expansion sleeve and tool a caulked slip joint around the liner perimeter. Without this bond break, heat expansion of the clay flue pipe will crack the concrete crown and admit freeze-thaw water into the masonry stack. Form a 2-inch overhang with a crisp underside drip groove so rainwater drops clear of the outer cinder block faces.

Calculation Assumptions & References Planning Reference

Material estimates depend on the selected dimensions, product yields, and waste allowance.

Content date: November 2026
Related references: IRC R1003 (Masonry Chimneys), NFPA 211 (Chimneys, Fireplaces & Vents), ASTM C90 / C129 (Masonry Units), ASTM C315 (Clay Flue Liners), ASTM C199 (Refractory Mortar), ASTM C270 (Type S Mortar). Confirm the applicable edition and local requirements.
A material estimate is not a structural design or code approval.
Masonry Q&A

Cinder Block Chimney & Flue Block FAQs

Code-referenced answers on 16×16 and 16×20 chimney blocks, 2-ft clay flue liners, refractory mortar, Type S mortar, and cast concrete crowns.

Standard chimney flue blocks measure 8 inches in nominal height (7-5/8 inches actual plus a 3/8-inch mortar joint), yielding 1.5 blocks per vertical foot. A 24-ft stack requires 24 × 1.5 = 36 net chimney blocks, or 38 blocks when adding a 5% waste and breakage allowance—plus 12 two-foot clay flue liner sections.