CMU Corner, Bullnose & Sash Jamb Block Dimensions

ASTM C90 & NCMA Modular Specialty Units•Actual 7-5/8" × 7-5/8" × 15-5/8" (8" Nominal)•3/4" Sash Groove & 1" Bullnose Radius
Standard 8-inch corner, bullnose, and sash jamb CMUs measure 7-5/8" × 7-5/8" × 15-5/8" actual (194 × 194 × 397 mm) with a 3/8-inch mortar joint. Sash jamb units add a 3/4" × 3/4" slotted channel; bullnose units round exposed edges to a 1-inch radius.
Sizing full structural wall runs or standard 4"–12" ASTM C90 block widths?

Advertisement

Technical architectural diagram showing CMU double-corner, bullnose, slotted sash jamb, half-jamb, and open-end H-block dimensions
ASTM C90 • Corner Return, Bullnose & Sash Jamb Series

CMU Corner, Bullnose & Sash Jamb Block Blueprint (8" Nominal)

Compare flat-end double-corner return units, 1" rounded bullnose edge blocks, and grooved 3/4" window sash jamb blocks.

L: 15-5/8" (15.625")H: 7-5/8" (7.625")W: 7-5/8" (7.625")Mode: Factory Actual Size (Before Mortar)
Face Shell Thickness1-1/4" min
Web Thickness1"–1-1/8" (Closed End)
Core / Cavity Spec1–2 Cores + 3/4"×3/4" Sash Groove or 1" Bullnose Radius
Modular Coverage1.125 units/sq ft • Flat end exposed at doors & turns
Corner & Jamb Spec

Corner, Bullnose & Sash Jamb CMU Estimator

Size corner/jamb specialty blocks per vertical wall return, window edge, and doorframe height.

Quick Dimension & Wall Presets:
Flat Double-Corner / Bullnose Blocks: 48 full units
Details ↓
Flat Double-Corner / Bullnose Blocks48 full units12 courses × 4 corners (square flat outer face)
16" Sash Jamb Full Units24 blocksGrooved 3/4" jamb track on alternating running-bond courses
8" Half Jamb Companion Units24 half blocksMaintains plumb opening edge on odd courses
Total Specialty Corner/Jamb Order96 unitsOrder alongside main stretcher pallet from local block plant
Dimensional Basis: Each vertical corner consumes 1 flat-end block per 8" course; each opening jamb alternates 16" sash jamb units and 8" half-jamb blocks.
Open Full Concrete Block Calculator
8" Full Unit Actual
7⅝" × 7⅝" × 15⅝"
194 × 194 × 397 mm (-3/8" joint)
Half-Jamb Actual
7⅝" × 7⅝" × 7⅝"
194 × 194 × 194 mm (1/2 module)
Sash Jamb Slot
3/4" × 3/4"
19 × 19 mm frame & shear key
Bullnose Edge
1" Radius
Single or double rounded arris

Corner, Bullnose & Sash Jamb CMU Specification Matrix (8-Inch Series)

ASTM C90 Modular Tolerances (±1/8")

Every specialty CMU shares the same 3/8-inch modular reduction as standard stretchers so corners, door openings, and window returns stay aligned with the 8-inch vertical and 16-inch horizontal grid. For an 8-inch nominal wall, full-length units are molded at 7-5/8" wide × 7-5/8" high × 15-5/8" long, and half-jamb units are molded at 7-5/8" long. Unit weights below are illustrative planning examples for medium-weight concrete blocks; verify local block-plant molds before ordering.

Specialty CMU TypeNominal Size (W×H×L)Actual Size (in)Metric (mm)End / Edge ProfileEst. Weight
Double-Corner (Plain-End)8" × 8" × 16"7-5/8" × 7-5/8" × 15-5/8"194 × 194 × 397Both ends flat & flush (square 90° edges)~36–38 lb
Single-Bullnose Corner8" × 8" × 16"7-5/8" × 7-5/8" × 15-5/8"194 × 194 × 397One 1" rounded vertical corner; 3 square edges~36–38 lb
Double-Bullnose Pier8" × 8" × 16"7-5/8" × 7-5/8" × 15-5/8"194 × 194 × 397Two 1" rounded edges on one end face~35–37 lb
Full Sash Jamb Block8" × 8" × 16"7-5/8" × 7-5/8" × 15-5/8"194 × 194 × 397Centered 3/4" × 3/4" vertical sash groove~35–37 lb
Half-Jamb / Control Jamb8" × 8" × 8"7-5/8" × 7-5/8" × 7-5/8"194 × 194 × 194Single core; flat or 3/4" grooved jamb end~18–20 lb
Open-End A-Block / H-Block8" × 8" × 16"7-5/8" × 7-5/8" × 15-5/8"194 × 194 × 3971 end open (A) or both ends open (H) for rebar~32–34 lb

Note: 6-inch (5-5/8" actual) and 12-inch (11-5/8" actual) corner, bullnose, and sash jamb blocks follow the same 7-5/8" height and 15-5/8" (or 7-5/8" half) length modules.

Double-Corner (Plain-End) vs. Single- & Double-Bullnose Corner Units

Double-Corner (Plain-End) Blocks

Standard stretcher CMUs carry recessed mortar-groove flanges (often called "ears") on both ends. If placed at an exterior 90-degree corner or free wall end, those open vertical slots leave unsightly hollow notches that trap water and chip easily.

A double-corner block eliminates both recessed end flanges so either end finishes completely smooth and square. Because its nominal thickness (8") equals half its nominal length (16"), alternating its direction at a 90-degree turn automatically produces an exact 8-inch running-bond offset on every course.

Single-Bullnose & Double-Bullnose Blocks

In schools, warehouses, corridors, and commercial kitchens, sharp 90-degree concrete block corners spall under cart impacts. Single-bullnose units mold a smooth 1-inch radius along one vertical edge while keeping the remaining three corners crisp and square for clean wall intersections.

Double-bullnose units round both exterior arrises on the exposed end face and are reserved for freestanding 8-inch partition ends, locker piers, and exposed pilasters. Masons typically install a square corner block at the base course or cap transition so baseboard trim and sills terminate cleanly.

Slotted Sash Jamb Channels, Half-Jambs & Control Joint Blocks

Doorways and window openings break a running-bond masonry wall every 8 inches vertically. To avoid slow field wet-saw cuts and weak open-cell edges, masons pair slotted sash jamb blocks with half-length jamb companions and control joint blocks.

1. 3/4" × 3/4" Sash Groove

Full 15-5/8" sash jamb blocks cast a centered 3/4-inch wide by 3/4-inch deep slot in the flat end shell. Steel window fins, wood buck anchors, and hollow-metal frame ties lock directly into this channel before mortar or sealant is applied.

2. Half-Jamb Companion Units

Odd courses need a 7-5/8" half-length unit at the opening edge to maintain the 50% bond offset. Half-jamb blocks match the 3/4" groove on one end and accept a normal stretcher head joint on the wall side.

3. Control Joint Shear Keys

At vertical shrinkage control joints (typically spaced 20–25 ft apart per NCMA TEK 10-2D), opposing sash-jamb grooves house a continuous cruciform rubber or PVC shear key while vertical bond is broken with building paper and backer rod/sealant.

Advertisement

Open-End H-Blocks, Rebar Dowel Transitions & Mortar / Grout Takeoffs

Corner cells and door/window jamb cores almost always carry vertical #4 or #5 deformed steel rebar dowels anchored into the concrete footing or lower bond beam. Lifting a closed-end 36-pound corner block over a 6-foot-tall vertical rebar dowel slows production and risks knocking freshly laid courses out of plumb. Open-end A-blocks (one end open) and knock-out H-blocks (both ends open, or knock-out web bond-beam units) slide horizontally around vertical dowels at floor level, then tie smoothly into continuous horizontal bond beams above openings.

Nominal Wall SizeActual WidthMin Face Shell (ASTM C90)Sash / Control GrooveCore Grout Vol / Full UnitMortar Factor (vs. 8" Base)
6" Corner & Jamb Series5-5/8" (143 mm)1" (25 mm)3/4" × 3/4" centered0.16 cu ft/unit0.8× (~37 units / 80-lb bag)
8" Corner & Jamb Series7-5/8" (194 mm)1-1/4" (32 mm)3/4" × 3/4" centered0.22 cu ft/unit1.0× (~30 units / 80-lb bag)
12" Corner & Jamb Series11-5/8" (295 mm)1-1/2" (38 mm)3/4" × 3/4" (or 1" key)0.35 cu ft/unit1.4× (~21 units / 80-lb bag)
Worked Jobsite Corner & Jamb Ordering Example (24×32 ft, 8-ft High Garage)

Suppose an 8-inch CMU garage measures 8 feet tall (12 courses), has 4 exterior corners, and includes 2 overhead/service doorways (4 vertical jamb edges total). Each corner needs 12 flat double-corner units (4 × 12 = 48 double-corner blocks). Each jamb edge alternates 6 full 16" sash jamb units and 6 half 8" jamb units (4 × 6 = 24 full sash jambs + 24 half-jamb blocks). Grouting all 4 corner cells and 4 jamb cells solidly uses roughly 8 vertical cells × 12 courses × 0.11 cu ft/half-cell = 10.6 cu ft of ASTM C476 grout (plus ~10% consolidation allowance). Always subtract these specialty corner/jamb counts from your main stretcher pallet order inside the Concrete Block Calculator so you do not double-order blocks.

Explore Related CMU Structural Dimension Guides

Calculation Assumptions & References Planning Reference

Material estimates depend on the selected dimensions, product yields, and waste allowance.

Content date: November 2026
Related references: ASTM C90, ASTM C270 (Type S / Type M Mortar), ASTM C476 (Grout), TMS 402/602 & IRC R606. Confirm the applicable edition and local requirements.
A material estimate is not a structural design or code approval.
Masonry Q&A

CMU Corner, Bullnose & Sash Jamb FAQs

Verified answers on flat-end corner units, 3/4-inch sash channels, open-end H-blocks, and running-bond jamb layouts.

A standard stretcher CMU has recessed mortar-keyed end flanges on both ends so head joints interlock cleanly in the middle of a wall. A double-corner (plain-end) CMU has flat, flush vertical faces on both ends, measuring 7-5/8" × 7-5/8" × 15-5/8" actual for an 8-inch unit, so exposed wall corners, pilasters, and door jambs finish completely square.

Advertisement